Concrete repair case studies structural repair structural repair structural repair structural repair structural repair

Leaking RC Pipe Joint Repair

The Problem

Ram-neck water stop failure at bell and spigot joint in RC pipe created infiltration and exfiltration.

The Solution

Working inside the pipe, Restruction Corporation installed a urethane multi-grout saturated jute and injected hydrophilic urethane grout into the joint. The system is called the “Expanded Gasket Technique” by the Bureau of Reclaimation.


Project Images

Inlet portion of the 96” diameter RC pipe water siphon
Inlet portion of the 96” diameter RC pipe water siphon
Installation of saturated jute
Installation of saturated jute
Inspection of grout penetration into test pipe joint
Inspection of grout penetration into test pipe joint
Jute ready for saturation
Jute ready for saturation
Injection of urethane multi-grout using plural component pump system and mixing head
Injection of urethane multi-grout using plural component pump system and mixing head